Protocolo de limpieza de suelos SSOP

trabajador fregando producto de espuma en el suelo
Compartir :

Mopping Stock Solution SSOP

Valor del tratamiento

Sterilex Ultra Disinfectant Cleaner Solution 1 (Solution 1) and Sterilex Ultra Activator Solution (Solution 2) function as a hard surface disinfectant. Applying the solution with a mop or squeegee allows for one step cleaning and disinfection on floor surfaces.

Products Used

  1. Sterilex Ultra Disinfectant Cleaner Solution 1
  2. Sterilex Ultra Activator Solution or Ultra Soft Metal Activator

Use of Sterilex PerQuat Solutions in a Stock Solution

Maintenance treatment is generally conducted at a minimum frequency of once per week and at a concentration of 12.8–16.0 fl oz of each solution per gallon of water. Refer to the products’ technical data sheets to ensure material compatibility with scrubber parts.

  1. Put on proper PPE. This includes goggles and/or face shield, protective clothing, and rubber gloves.
  2. Prepare a stock solution of Sterilex Ultra Disinfectant Cleaner Solution 1 and Sterilex Ultra Activator Solution.
    1. Fill a graduated, 5-gallon bucket with 2 gallons of water.
    2. Add 32 fl oz (1 qt) of Sterilex Ultra Disinfectant Cleaner Solution 1 to the bucket.
    3. Add 32 fl oz (1 qt) of Sterilex Ultra Activator Solution to the bucket. The bucket should be filled to the 2.5 gal (10 qt) line.
    4. For larger volumes, the same ratios can be applied adding 16 fl oz (0.5 qt) of Sterilex Ultra Disinfectant Cleaner Solution 1 and 16 fl oz (0.5 qt) of Sterilex Ultra Activator Solution for each additional gallon of water.
  3. Add stock solution to a mop or utility bucket and apply using a mop or squeegee.
  4. Allow surfaces to remain visibly wet for AT LEAST 10 minutes.
  5. Rinse all food contact surfaces thoroughly with a potable water rinse. For non-food contact surfaces wipe, rinse, or allow surface to air dry.

Notas de uso
All stock solutions must be used within 8 hours. Pour any excess stock solution down a sanitary drain. For application on hard, non-porous surfaces only. Directions for use are consistent with those for Feline calicivirus. See product label for details.

Rellene el formulario para descargar el PDF
Ponte en contacto

Si desea información sobre un producto concreto, necesita asistencia técnica, quiere saber cómo hacer un pedido o simplemente quiere decirnos cómo nos va, póngase en contacto con nosotros hoy mismo.