Protocolo de fregado de suelos SSOP

trabajador fregando producto de espuma en el suelo
Compartir :

Use of Sterilex PerQuat® Solutions in Floor Scrubbers

Valor del tratamiento

Sterilex Ultra Disinfectant Cleaner Solution 1 (Solution 1) used in conjunction with Sterilex Ultra Activator Solution (Solution 2) function as a hard surface disinfectant. Applying the solution with a floor scrubber allows for one-step cleaning and disinfection on floor surfaces.

After cleaning, Sterilex Ultra Step or ProvaStride are two options for EPA-registered dry floor sanitizers that can be applied directly to production floors for additional protection from cross-contamination. Both products are formulated to add traction and prevent slippage. See the product application guides for more information.

Protocol for Maintenance Treatment

Maintenance treatment is generally conducted at a minimum frequency of once per week and at a concentration of 12.8–16.0 fl oz of each solution per gallon of water. Refer to the products’ technical data sheets to ensure material compatibility with scrubber parts.

  1. Clean floor by removing all large particles and gross visible soils from the floor surface.
  2. Mix a solution consisting of Solution 1 (use Sterilex Ultra CIP if low foaming is desired), Solution 2 (use Ultra Soft Metal Activator if using on compatible* soft metals) and water. The solution should be mixed at a rate of 12.8–16.0 fl oz of Solution 1 or Sterilex Ultra CIP and 12.8–16.0 fl oz of Solution 2 per gallon of water.
    • Add the proper amount of both chemicals to the correct volume of water in the scrubber.
    • Mix the solution. If possible, agitate to ensure proper mixing.
  3. Apply the Sterilex solution to the floor using the scrubber. Add additional mixed solution when necessary. Allow floor to remain visibly wet for 10 minutes.
  4. Thoroughly rinse the floor scrubber holding tank, and fill with potable water.
  5. Apply water to the floor surface, using the scrubber.

*See Ultra Soft Metal Activator compatibility chart.

Notas de uso
Sterilex recomienda utilizar los productos dentro de las 8 horas siguientes a la mezcla. Si es necesario utilizar la mezcla después de 8 horas, utilice el kit de prueba para garantizar la concentración adecuada de ingrediente activo. Mezcle tanta solución como sea necesaria para la aplicación específica.

Rellene el formulario para descargar el PDF
Ponte en contacto

Si desea información sobre un producto concreto, necesita asistencia técnica, quiere saber cómo hacer un pedido o simplemente quiere decirnos cómo nos va, póngase en contacto con nosotros hoy mismo.