Recommended SSOP for Drains
Sterilex Ultra Disinfectant Cleaner Solution 1 (Solution 1) used in conjunction with Sterilex Ultra Activator Solution (Solution 2), is designed to enhance an existing sanitation program and solve the most difficult sanitation challenges. Implementation of a comprehensive Sterilex drain program has been proven to eliminate environmental positives, treat harborage niches, kill biofilm bacteria and remove biofilm.
Reminder: Drain sanitation should be conducted after proper cleaning of equipment, environmental surfaces, and floors.
Pre-Cleaning
- For floor drains, remove the basket from the drain and empty gross debris into a waste receptacle.
- For drain cavities containing heavy fats and grease, foam drain with a caustic cleaner and follow with a thorough water rinse. If heavy fats and greases are not present Solution 1 and Solution 2 act as a one-step cleaner/ disinfectant/ biofilm removal agent for drains.
Sanitation + Biofilm Removal with Sterilex PerQuat® Liquids
- Add 12.8 oz of Solution 1 and 12.8 oz of Solution 2 per gallon of water (1:1:10) to the tank foamer.
- Recommendation: Attach stainless steel drain foam attachment to a dedicated tank foamer.
- Place the drain attachment disk over the top of the drain and apply foam to the drain until the entire drain cavity is covered by thick, shaving cream-type foam.
- For floor drains, replace the basket and foam until the basket is covered with foam.
- There is no need to rinse the drain following the application of Solution 1 and Solution 2. The foam should subside in 10–15 minutes.
- When the foam has dissipated, add a ProvaGrate drain ring (pictured) for extended protection between treatments.
Usage Notes
- Once mixed, the Sterilex solution MUST be used within 8 hours.
- Water temperature should be in the range of 100°F to 145°F.
- When beginning a treatment program, Sterilex recommends a shock treatment, foaming drains daily for 1–2 weeks. After shock treatment, plants typically reduce usage to 1–2 times per week, or as demanded by a microbial monitoring program.